Achieving CSH Level 3- Exemplar 2a - 2 Storey Mid Terrace House - MECHANICAL VENTILATION WITH HEAT RECOVERY APPROACH
BUILT FORM
Mid terrace 2 storey house
Ground floor area 43.94m2, first floor area 43.94m2
Sheltered sides = 2
THERMAL ENVELOPE
'U' values for external elements
VENTILATION
Design air permeability = 3.0 m3/hour/m2 at 50 Pa
Mechanical ventilation system with heat recovery (system SAP Appendix Q registered)
Kitchen + 2 additional wet rooms
Rigid, insulated ductwork
Specific fan power = 1.0 w/l/s
Heat exchange efficiency = 85%
HEATING AND HOT WATER
Gas fired condensing combi boiler - 90.3% efficient, SEDBUK band A
No secondary heating to lounge
LIGHTING
10 no. fixed dedicated low energy light fittings
CONSTRUCTION DETAILS
Accredited construction details used
SPECIAL FEATURES
Flue gas heat recovery system applied to boiler.